Review




Structured Review

Zimmer Biomet tibial component
Tibial Component, supplied by Zimmer Biomet, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tibial+components/component/pmc13202488-72-10-16
Average 86 stars, based on 1 article reviews
tibial component - by Bioz Stars, 2026-10
86/100 stars

Images

Related Articles

other:

Article Title: One-stage exchange arthroplasty for periprosthetic joint infection following total knee arthroplasty with sinus tract: a mid-to short-term follow-up study
Article Snippet: Constrained femoral and tibial components (Zimmer Biomet, USA) were implanted.

Article Title: Development of Methods for Analyzing Tibiofemoral Kinematics and Contact Kinematics using 3D Models
Article Snippet: Unrestricted kinematically aligned TKA was performed on ten fresh-frozen cadaveric knee specimens using manual instruments (Howell et al., 2013), a transpatellar approach (Merican et al., 2009), and cruciate retaining femoral and tibial components (Persona, Zimmer Biomet, Warsaw, IN) implanted without ligament release.

Article Title: One-stage exchange arthroplasty for periprosthetic joint infection following total knee arthroplasty with sinus tract: a mid-to short-term follow-up study.
Article Snippet: Constrained femoral and tibial components (Zimmer Biomet, USA) were implanted.

Article Title: Relative Motion of Cementless Tibial Trays: Time-Elapsed Micro-CT and DVC Analysis During Stair Descent and Deep-Knee-Bend.
Article Snippet: Both papers employed different tibial components (NexGen LPS, Zimmer Biomet and e.motion Knee System, Aesculap, respectively) to that used here.



Similar Products

86
Zimmer Biomet tibial component
Tibial Component, supplied by Zimmer Biomet, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tibial+components/component/pmc13202488-72-10-16
Average 86 stars, based on 1 article reviews
tibial component - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Zimmer Biomet tibial components
Tibial Components, supplied by Zimmer Biomet, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tibial+components/components+tibial/pm42118232-238-4-8
Average 86 stars, based on 1 article reviews
tibial components - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Zimmer Biomet cementless tm tibial component
Cementless Tm Tibial Component, supplied by Zimmer Biomet, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tibial+components/insert+polyethylene/pm41752695-133-14-27
Average 86 stars, based on 1 article reviews
cementless tm tibial component - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Johnson & Johnson tibial components
Demonstration of mid-flexion instability. (a and b) Preoperative anteroposterior and lateral radiographs of a 58-year-old female with a painful Microport Evolution pivot total knee system. Despite being well fixed and aligned, the knee exhibited mid-flexion instability. (c and d) Postoperative anteroposterior and lateral radiographs of the same patient. During surgery, the <t>components</t> were confirmed to be well fixed, and the polyethylene insert thickness was increased from a 12-mm cruciate-sacrificing insert to a 17-mm cruciate-sacrificing insert. This adjustment resulted in equal flexion and extension gaps. At 2 years postoperatively, the patient is pain-free with a range of motion from 0° to 125°.
Tibial Components, supplied by Johnson & Johnson, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tibial+components/components/pmc12446502-151-9-13
Average 86 stars, based on 1 article reviews
tibial components - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
Zimmer Biomet cruciate retaining trabecular metal nexgen tibial component
Demonstration of mid-flexion instability. (a and b) Preoperative anteroposterior and lateral radiographs of a 58-year-old female with a painful Microport Evolution pivot total knee system. Despite being well fixed and aligned, the knee exhibited mid-flexion instability. (c and d) Postoperative anteroposterior and lateral radiographs of the same patient. During surgery, the <t>components</t> were confirmed to be well fixed, and the polyethylene insert thickness was increased from a 12-mm cruciate-sacrificing insert to a 17-mm cruciate-sacrificing insert. This adjustment resulted in equal flexion and extension gaps. At 2 years postoperatively, the patient is pain-free with a range of motion from 0° to 125°.
Cruciate Retaining Trabecular Metal Nexgen Tibial Component, supplied by Zimmer Biomet, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tibial+components/cruciate+retaining+trabecular+metal+nexgen+tibial+component/pm40583255-30-15-21
Average 90 stars, based on 1 article reviews
cruciate retaining trabecular metal nexgen tibial component - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Demonstration of mid-flexion instability. (a and b) Preoperative anteroposterior and lateral radiographs of a 58-year-old female with a painful Microport Evolution pivot total knee system. Despite being well fixed and aligned, the knee exhibited mid-flexion instability. (c and d) Postoperative anteroposterior and lateral radiographs of the same patient. During surgery, the components were confirmed to be well fixed, and the polyethylene insert thickness was increased from a 12-mm cruciate-sacrificing insert to a 17-mm cruciate-sacrificing insert. This adjustment resulted in equal flexion and extension gaps. At 2 years postoperatively, the patient is pain-free with a range of motion from 0° to 125°.

Journal: Arthroplasty Today

Article Title: Defining “Paradoxical Instability” and Other Indications for Aseptic Single-Component Polyethylene Revision: A Cohort Study Including Mid-flexion Instability and Limited Arc of Motion

doi: 10.1016/j.artd.2025.101835

Figure Lengend Snippet: Demonstration of mid-flexion instability. (a and b) Preoperative anteroposterior and lateral radiographs of a 58-year-old female with a painful Microport Evolution pivot total knee system. Despite being well fixed and aligned, the knee exhibited mid-flexion instability. (c and d) Postoperative anteroposterior and lateral radiographs of the same patient. During surgery, the components were confirmed to be well fixed, and the polyethylene insert thickness was increased from a 12-mm cruciate-sacrificing insert to a 17-mm cruciate-sacrificing insert. This adjustment resulted in equal flexion and extension gaps. At 2 years postoperatively, the patient is pain-free with a range of motion from 0° to 125°.

Article Snippet: This necessitated complex second revision TKA of femoral and tibial components using a Johnson & Johnson Depuy Attune revision total knee system 8 months postoperatively.

Techniques:

Demonstration of flexion contracture. (a and b) Preoperative anteroposterior and lateral radiographs of a 56-year-old male with a Microport Evolution medial pivot total knee system showing flexion contracture. (c and d) Postoperative anteroposterior and lateral radiographs of the same patient. Intraoperatively, the components were verified as well-fixed, and the polyethylene insert thickness was reduced from a 12-mm cruciate-sacrificing insert to a 10-mm cruciate-sacrificing insert. This modification led to an improvement in flexion contracture. Two years postoperatively, the patient is pain-free with a ROM from 0 to 105°.

Journal: Arthroplasty Today

Article Title: Defining “Paradoxical Instability” and Other Indications for Aseptic Single-Component Polyethylene Revision: A Cohort Study Including Mid-flexion Instability and Limited Arc of Motion

doi: 10.1016/j.artd.2025.101835

Figure Lengend Snippet: Demonstration of flexion contracture. (a and b) Preoperative anteroposterior and lateral radiographs of a 56-year-old male with a Microport Evolution medial pivot total knee system showing flexion contracture. (c and d) Postoperative anteroposterior and lateral radiographs of the same patient. Intraoperatively, the components were verified as well-fixed, and the polyethylene insert thickness was reduced from a 12-mm cruciate-sacrificing insert to a 10-mm cruciate-sacrificing insert. This modification led to an improvement in flexion contracture. Two years postoperatively, the patient is pain-free with a ROM from 0 to 105°.

Article Snippet: This necessitated complex second revision TKA of femoral and tibial components using a Johnson & Johnson Depuy Attune revision total knee system 8 months postoperatively.

Techniques: Modification

Demonstration of paradoxical instability. (a and b) Preoperative anteroposterior and lateral radiographs of a 72-year-old female with a Zimmer Biomet Persona posterior-stabilized total knee system, showing mid-flexion instability and flexion contracture, referred to as paradoxical instability. (c and d) Postoperative anteroposterior and lateral radiographs of the same patient. Intraoperatively, the components were confirmed to be well-fixed, and the polyethylene insert thickness was increased from a 12-mm cruciate-sacrificing insert to a 16-mm cruciate-sacrificing insert. This modification resulted in balanced flexion and extension gaps. Two years postoperatively, the patient is pain-free with a ROM from 0° to 125°.

Journal: Arthroplasty Today

Article Title: Defining “Paradoxical Instability” and Other Indications for Aseptic Single-Component Polyethylene Revision: A Cohort Study Including Mid-flexion Instability and Limited Arc of Motion

doi: 10.1016/j.artd.2025.101835

Figure Lengend Snippet: Demonstration of paradoxical instability. (a and b) Preoperative anteroposterior and lateral radiographs of a 72-year-old female with a Zimmer Biomet Persona posterior-stabilized total knee system, showing mid-flexion instability and flexion contracture, referred to as paradoxical instability. (c and d) Postoperative anteroposterior and lateral radiographs of the same patient. Intraoperatively, the components were confirmed to be well-fixed, and the polyethylene insert thickness was increased from a 12-mm cruciate-sacrificing insert to a 16-mm cruciate-sacrificing insert. This modification resulted in balanced flexion and extension gaps. Two years postoperatively, the patient is pain-free with a ROM from 0° to 125°.

Article Snippet: This necessitated complex second revision TKA of femoral and tibial components using a Johnson & Johnson Depuy Attune revision total knee system 8 months postoperatively.

Techniques: Modification